Inverter Hybrid Boiler

Inverter hyb rid

Characteristic

  • Saving energy inverter, heating hot water to 80 degree over heat pump technology
  • Connected with a heat pump outdoor unit, heat pump makes heating, floor heating, hot water possible
  • Minimized CO2 emmision eco-friendly high efficiency eco-green system
  • Saving the electricity at about 60% saving less than existing midnight electricity
  • Lightest, moving and easy to installation separate type system
  • Easy to use by operating of remote control at smart mobile
Inverter Hybrid Heat Pump?

Flow Diagram

Standard Specification

Item KEPCO-Type Commercial-Type
AWH-025XB AWB-016V AWC-025X AWD-025XB
Raged Heating Capacity(Kw) 25 16.5 25 25
Rated Power Consumption(Kw) 10.4 5.55 10 10.4
Rated Operation Current(A) 18 27 17.5 18
Max.Power Consumption(Kw) 14.5 9 11.8 14.5
Cold climate area heaing capacity(Kw) 20 11.5 18 20
Cold climate area Power Consumption(Kw) 13.1 6.6 11.8 13.1
Combined Efficiency KSCOP_C 25 - - 2.5
Flow Rate(LPM) Recommended flow rate 40-50
(Recommended))
35-40
(Recommended))
35-40
(Recommended))
40-50
(Recommended))
Ues range 30-70 20-60 20-60 30-70
Inlet Temp.(℃) Standard 40 40 40 40
Use range 15-80 15-80 15-80 15-80
Outlet Temp. Standard 80(Max.85) Standard 80(Max.85) Standard 80(Max.85) Standard 80(Max.85)
Power 3Φ 380V 60Hz 1Φ 220V 50Hz/60Hz 3Φ 380V 50Hz/60Hz 3Φ 380V 50Hz/60Hz
Refrigerant R-410a[3,500g]
R-134a[1,900g]
R-410a[2,200g]
R-134a[1,400g]
R-410a[2,540g]
R-134a[1,800g]
R-410a[3,500g]
R-134a[1,900g]
Compressor Type Scroll/Twin Rotary Twin Rotary Twin Rotary Scroll/Twin Rotary
Method Scroll/Twin Rotary Twin Rotary Twin Rotary Scroll/Twin Rotary
Control of capacity Inverter/Inverter Inverter Inverter Inverter/Inverter
Dimension
(L x W x H)
Outdoor unit 565 x 1,286 x 1,440
[Base included]
320 x 900 x 1,360 320 x 900 x 1,360 565 x 1,286 x 1,440
[Base included]
Indoor unit 440 x 818 x 1,110
[Base included]
330 x 570 x 1,030 330 x 570 x 1,030 440 x 818 x 1,110
[Base included]
Weight(Kg) Outdoor unit 125 / Indoor unit 99 Outdoor unit 86 / Indoor unit 78 Outdoor unit 95 / Indoor unit 93 Outdoor unit 125 / Indoor unit 99
Earth leakage breaker(3Φ) 30A
Indoor Unit Heat exchanger(Type) Plate type(R410a:R134a)
Refrigerant : Refrigerant
Heat exchanger(Type) Plate type(R410a:hot water)
Refrigerant : Hot water Hot water pressure drop : 4[2~9] kPa
Refigerant Piping
(R410A)
Liquid pipe(mm) 9.52
Gas pipe(mm) 15.88
Indoor unit
Water piping
Inlet(mm) 25A
Outlet(mm)
Indoor temperature use range(℃) 5~40
Outdoor temperature use range(℃) Standard -20~40
  • Period

    1. Standard of Heating Capacity : Outside condition 7℃ DB / 6WB, Indoor condition 20DB /15WB, Recovery temperature 40℃, Flow rate 23LPM, length of pipe 5m, Head 0m/ability, Power consumption and etc can be changed without notice depending on the developed product.
    2. Standard of Heating : Outdoor temperature 7℃, it can be changed depending on the temperature change.
    3. Use the Hydro unit and outdoor IEC 60245-4, IE666, H07RN-F power line and higher.
    4. Hydroelectric and outdoor unit is the standard installation length to the panel board.

Purpose of Use

Bathing Facilities/Accommodation Facilities
  • Steam baths
  • Saunas
  • Steam rooms
  • Swimming pool
  • Hotels
  • Motels
  • Dormitories
  • Training centers
  • Nursing homes
  • Pension
  • Condo
  • Studio apartment
Agricultural Facilities/Religious Facilities
  • Vinyl greenhouse
  • Floricultural Pot
  • Raising seedlings
  • Pig farming, Fish farm
  • Churches
  • Cathedrals
  • Temples
  • Prayer house
For Public Facilities
  • Hospitals
  • Schools
  • Shops
  • Factories
  • Office building